Briggs & Stratton PowerProtect DX 26kW (040806) vs Generac Guardian 26kW with 200A ATS (7291)
Both units carry the same best-fuel running rating: 26,000 W. The Briggs & Stratton PowerProtect DX 26kW (040806) is the quieter of the two (65 dBA vs 67 dBA — though manufacturers measure noise at different loads and distances). Warranty favors the Briggs & Stratton PowerProtect DX 26kW (040806): 10 years vs 5.
| Briggs & Stratton PowerProtect DX 26kW (040806) | Generac Guardian 26kW with 200A ATS (7291) | |
|---|---|---|
| Type | home-standby | home-standby |
| Fuel | natural-gas, propane | natural-gas, propane |
| Running watts (gas / LP for standby) | 26000 W | 26000 W |
| Running watts (propane) | 26000 W | 26000 W |
| Running watts (natural gas) | 24000 W | 22500 W |
| Noise level | 65 dBA | 67 dBA |
| Output voltage | 120/240V | 120/240V |
| Automatic transfer switch included | No | Yes |
| Main-line circuit breaker | 125 A | 110 A |
| Start type | automatic | automatic |
| Engine | Briggs & Stratton Vanguard | Generac G-Force 1000 |
| Engine displacement | 993 cc | 999 cc |
| NG use at half load | 206 ft³/h | 188 ft³/h |
| Propane use at half load | 2.57 gal/h | 2.06 gal/h |
| Weight | 540 lb | 518 lb |
| Warranty | 10 yr | 5 yr |
Frequently asked questions
Which costs less to run, the Briggs & Stratton PowerProtect DX 26kW (040806) or the Generac Guardian 26kW with 200A ATS (7291)?
Estimated fuel for 24 hours at about 50% load: $74 on natural gas for the Briggs & Stratton PowerProtect DX 26kW (040806) vs $67 on natural gas for the Generac Guardian 26kW with 200A ATS (7291), at national average prices. These are spec-sheet-derived estimates — the assumptions are on the methodology page, and different fuels make this a cost comparison, not an efficiency ranking.
Where do these specifications come from?
Every record on BackupAtlas is hand-curated from manufacturer documentation and spec sheets, and each generator page links to its source document.