Generator glossary

Short, direct answers to the terms that come up when choosing backup power.

50-amp inlet (14-50 / CS6365)
Large portable generators above the 7,200 W ceiling of a 30 A connection use a 50-amp, 120/240 V connector — either a straight-blade 14-50R (the “RV/range” outlet) or a CS6365 twist-lock — carrying up to 12,000 watts into a 50 A generator inlet.
Automatic transfer switch (ATS)
An automatic transfer switch monitors utility power and switches the house to generator power without human action — it signals a standby generator to start, transfers the load once output is stable, and transfers back when the utility returns.
CO safety shutoff
A CO safety shutoff is a built-in carbon monoxide sensor that stops the generator’s engine automatically when CO accumulates around the unit — sold under names like CO-MINDER, CO Shield, CO Guard, and CO Sense. It is a backstop, not a license to run a generator near the house.
Dual fuel
A dual-fuel generator runs on either gasoline or propane, switched by a selector and a regulator. Propane stores indefinitely and stays available when storms close gas stations, at the cost of roughly 10% less output than the gasoline rating.
EPA / CARB compliance
All new generators sold in the US must meet EPA emissions standards; CARB compliance is California’s stricter certification, required to sell a generator in California. Neither is a performance rating — they certify exhaust and evaporative emissions.
Floating vs bonded neutral
A bonded-neutral generator connects its neutral to the frame (its own ground); a floating-neutral generator leaves them separate, expecting the building’s panel to provide the bond. The wrong pairing with a transfer switch can trip GFCIs or defeat ground-fault protection.
Generator cord gauge
Cord gauge (AWG) sets how much current a generator cord can carry safely and how much voltage it loses over distance: 10 AWG for 30 A circuits, 6 AWG for 50 A, and thicker (lower-number) wire the longer the run.
Interlock kit
An interlock kit is a sliding metal plate on the breaker panel that makes it mechanically impossible to close the generator backfeed breaker while the main breaker is on. It is the low-cost alternative to a transfer switch for connecting a portable generator.
Inverter generator
An inverter generator converts its alternator’s raw output to DC and re-synthesizes clean AC electronically, producing low-distortion power at any engine speed. The result is quieter operation, better fuel economy at partial load, and output safe for sensitive electronics.
L14-30R outlet
The L14-30R is the standard 30-amp, 120/240-volt twist-lock receptacle found on most mid-size portable generators. It carries up to 7,200 watts through a single cord and is the usual connection point for a transfer switch or interlock.
Load shedding
Load shedding is automatically dropping lower-priority circuits when generator demand approaches capacity — letting a smaller standby generator protect a whole panel by making sure the air conditioner and dryer never run at the same time.
Parallel kit
A parallel kit is a cable set that links two inverter generators so their outputs combine into one circuit — two 2,200 W units become roughly 4,000 W of capacity. Only inverter generators designed for paralleling (usually matched models) support it.
Propane BTU content
Propane carries about 91,500 BTU per gallon — the number that converts a generator’s gallons-per-hour appetite into runtime from a given tank. A 20 lb grill cylinder holds about 4.6 gallons (~420,000 BTU); gasoline carries about 114,000 BTU per gallon.
Run time rating (at 25% / 50% load)
Generator runtimes are quoted at a fraction of rated load — usually 25% or 50% — on a full tank. A “12 hours at 50%” unit running near full load may manage only 5–6 hours, so match the load fraction to how you will actually use it.
Starting watts vs running watts
Running watts is the power a generator sustains continuously; starting watts is the extra surge it can supply for a few seconds while a motor spins up. Size a generator so running loads fit the running rating and the single largest motor start fits within the starting rating.
Total harmonic distortion (THD)
THD measures how far a generator’s AC output deviates from a pure sine wave, as a percentage. Under 5% THD is generally considered safe for sensitive electronics; conventional open-frame generators can exceed 15–25%, while inverter generators typically stay under 3%.
Transfer switch
A transfer switch is a device that connects a generator to a home’s circuits while physically disconnecting them from the utility line, so generator power can never backfeed the grid. It is the code-required way to power hardwired circuits from a generator.
Tri-fuel
A tri-fuel generator runs on gasoline, propane, or natural gas. The natural-gas option lets a portable unit draw unlimited fuel from the home’s gas meter — with the lowest output of the three fuels, typically about 20% below the gasoline rating.