Westinghouse WGen12000DF is a portable generator from Westinghouse, rated 12,000 running watts with 15,000 starting watts on gasoline (10,800 W on propane), with 120/240V output.
| Type | portable |
|---|---|
| Fuel | gasoline, propane |
| Running watts (gas / LP for standby) | 12000 W |
|---|---|
| Starting watts (gas) | 15000 W |
| Running watts (propane) | 10800 W |
| Starting watts (propane) | 13500 W |
| Fuel tank | 10.5 gal |
|---|
| Output voltage | 120/240V |
|---|---|
| Transfer-switch-ready outlet | 50 A |
| Outlets | 2x 5-20R, L5-30R, L14-30R, 14-50R, 2x USB |
| Start type | remote electric |
|---|
| Engine displacement | 713 cc |
|---|
| Weight | 352 lb |
|---|
What the numbers mean
- At 12,000 running watts on its best fuel, this unit covers most household circuits through an appropriately sized transfer switch; central air conditioning typically needs load management or a soft starter.
- Runs on gasoline, propane — expect lower output on propane (roughly 10%) and natural gas (roughly 20%) than on gasoline; the spec table shows the published per-fuel ratings.
- House hookup: pairs with a 50 A generator inlet ( 14-50 / CS6365) and a transfer switch or interlock installed by an electrician.
Compare the Westinghouse WGen12000DF
- Westinghouse WGen12000DF vs DuroMax XP12000EH Dual Fuel
- Westinghouse WGen12000DF vs DuroMax XP13000EH Dual Fuel
- Westinghouse WGen12000DF vs DuroMax XP13000HX Dual Fuel with CO Alert
- Westinghouse WGen12000DF vs DuroMax XP15000HX Dual Fuel
- Westinghouse WGen12000DF vs Firman H08051 Dual Fuel 8000W
- Westinghouse WGen12000DF vs Firman T08071 Tri-Fuel 8000W
- Westinghouse WGen12000DF vs Generac GP17500E
- Westinghouse WGen12000DF vs Generac GP8000E COsense
Similar generators
- DuroMax XP15000HX Dual Fuel ( 12,000 W running)
- Westinghouse WGen11500TFc Tri-Fuel ( 11,500 W running)
- DuroMax XP13000EH Dual Fuel ( 10,500 W running)
- DuroMax XP13000HX Dual Fuel with CO Alert ( 10,500 W running)
- Predator 13000 Tri-Fuel (71386) ( 10,000 W running)
- DuroMax XP12000EH Dual Fuel ( 9,500 W running)
Frequently asked questions
What can the Westinghouse WGen12000DF run during an outage?
With 12,000 running watts on its best fuel, the Westinghouse WGen12000DF covers most household circuits through an appropriately sized transfer switch; central air conditioning typically needs load management or a soft starter. Add up your actual loads with a sizing worksheet — the bands here are rough guidance, not a load calculation.
What inlet does the Westinghouse WGen12000DF need to power a house?
A 50 A generator inlet (a 14-50 or CS6365 connection) wired to a transfer switch or interlock kit — an electrician's job that normally requires a permit. Never backfeed through a dryer or wall outlet.